steam boiler Agent 6000 pounds of steam per hour

steam boiler Agent 6000 pounds of steam per hour

Energy Tips – Steam

pounds per hour (lb/hr) of saturated steam for process loads. The plant operates two shifts per day, with the boiler operating at rated capacity for 6,000 hours/year. The boiler has reached the end of its service life and the company is considering replacing the boiler with a new 100-psig boiler or with a high-pressure 600-psig

Get A Quote

Guide to Inspections of Low Acid Canned Food 13 | FDA

A standard three or four crate vertical still steam retort can require from 2,500 to 6000 lbs of steam per hour (depending upon the size of the steam inlet) during venting. One-fourth to one-half

Get A Quote

Steam Pipe Capacities Table

Steam Pipe Capacities Table Steam Pipe Capacities Table Steam Pipe Capacities POUNDS PER HOUR OF SATURATED STEAM AT GAUGE PRESSURES SHOWN AND IN PRESSURE DROPS PER 100 FEET OF PIPE 5PSIG 15PSSIG 25PSIG PipeSze 1/4 1/2 1/4 1/2 1 1/2 1.00 1.5 3/4 18 27 24 35 47 40 60 75 1 35 55 47 70 95 80 120 150 1-1/4 80 120 100 140 200 160 240 300

Get A Quote

Steaming Rate - Industrial Steam Boilers Manufacturers

Unit Conversion--How to Calculate Boiler Horsepower

Get A Quote

steam generator 1000 kg per hours

However, if a steaming rate is used to specify boiler size then the steaming rate must be qualified—"from and at 212°F"; gross or net; pounds or kilograms per hour. Clayton Steam Generators are available in many sizes and as portable steam boilers. Many are available as medium pressure steam boilers and high pressure steam boilers for sale.

Get A Quote

Pipe Sizing Steam Supply andCondensateReturn Lines

Assume a boiler operates at a steam pressure of 15 psig and is supplying a 300-ton steam absorption machine which requires a minimum operating pressure of 12 psig. There is a 2 psig pressure drop along the steam mains and the absorption machine is rated to condense 6,000 lbs/hr. The branch line is 50 feet long and has three standard elbows plus

Get A Quote

Pipe Sizing Steam Supply andCondensateReturn Lines

26 rows · Dec 13, 2010 · Heating Water with Steam Example: How many lbs per hour of steam is need …

Get A Quote

13 NCAC 13 .0411 VALVES, DRAINS, AND BOTTOM BLOWOFFS

(4) Steam heating boilers having a minimum safety valve relieving capacity greater than 6000 pounds of steam per hour shall have a blowoff outlet of not less than 2 inches NPS; and (5) All other steam heating boilers shall have a blowoff outlet of not less than 1 inch NPS.

Get A Quote

FOOD INDUSTRY BEST PRACTICES PROGRAM Campbell …

The Steam ESA identifies that Boiler # 3 is producing 137,400 pounds of steam per hour at 250 psig, but only 72,000 pounds of 250 psig steam per hour are used by the Multipurpose evaporation system. The remaining 65,400 pounds of steam is passing through the pressure reducing valve (PRV) to deliver 150 psig steam to additional end-use assets.

Get A Quote

Pipe Sizing Steam Supply and Condensate Return Lines

PRESSURE DROP, PSI PER 100 FT PRESSURE DROP, OUNCES PER SQ IN PER 100 FT SATURATED STEAM PRESSURE, PSIG SATURATED STEAM PRESSURE, PSIG FLOW RATE, POUNDS PER HOUR FLOW AND VELOCITY BASED ON . 0. PSIG. Chart CG-25. Flow Rate and Velocity of Steam in Schedule 40 Pipe at Saturation Pressure of 0 psig. 56. 838_Cons_Guide.qxd 11/4/03 2:50 PM Page CG

Get A Quote

Steam Capacity Conversion Table | Industrial Controls

Boiler Capacity - Engineering ToolBox

Get A Quote

Miscellaneous Industrial Costs - Michigan

Packaged boilers are rated on the basis of maximum continuous nozzle output, in terms of boiler horsepower, B.T.U. per hour, or pounds of steam per hour at 212° F. Available information can be converted to horsepower by using the table below. 1 boiler horsepower = 33,500 B.T.U. per hour = 139 square feet of steam radiation

Get A Quote

Steam Calculators: Boiler Calculator

Mar 17, 2015 · Steam, Boiler, and Blowdown Pressure are the same. Combustion Efficiency is the % of fuel energy that is directly added to the feedwater and not otherwise lost or used. Blowdown Rate is the % of incoming feedwater mass flow rate that leaves the boiler as a saturated liquid at boiler pressure.

Get A Quote

Guide to Inspections of Low Acid Canned Food 13

Nov 25, 2014 · A standard three or four crate vertical still steam retort can require from 2,500 to 6000 lbs of steam per hour (depending upon the size of the steam inlet) during venting. One-fourth to one-half

Get A Quote

13 NCAC 13 .0411 VALVES, DRAINS, AND BOTTOM BLOWOFFS

of steam per hour but not greater than 6000 pounds of steam per hour shall have a blowoff outlet of not less than 1 1/2 inches NPS; (4) Steam heating boilers having a minimum safety valve relieving capacity greater than 6000 pounds of steam per hour shall have a blowoff outlet of …

Get A Quote

STEAM REQUIREMENTS OF RETORTS

1¼ inch inlet 3500 pounds of steam/hour 100.0 bhp 1½ inch inlet 4500 pounds of steam/hour 130.0 bhp 2 inch inlet 6000 pounds of steam/hour 174.0 bhp Note that these are possible peak rates. You probably won't reach them. If you are cooking two 5-car retorts with 1½ inch steam inlets and bringing up a third you could be using 15 bhp in each

Get A Quote

Boiler Capacity - Engineering ToolBox

Steam Capacity Conversion Table | Industrial Controls

Get A Quote

Unit Conversion--How to Calculate Boiler Horsepower

steam table. Total Heat of Steam (Column 6). The sum of the Heat of the Liquid (Column 4) and Latent Heat (Column 5) in Btu. It is the total heat in steam above 32°F. Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound. Specific Volume of Steam (Column 8). The volume per unit of mass in cubic feet per

Get A Quote

Boiler Steam Calculator - Cleaver-Brooks

Horsepower (hp) can be converted into lbs of steam by multiplying hp with 34.5. Example - Boiler Horsepower to lbs of Steam Conversion. 200 hp x 34.5 = 6900 lbs of steam per hour. Lbs of steam can be converted to hp by dividing lbs steam per hour by 34.5. Example - Lbs of Steam to Boiler Horsepower Conversion. 5000 lbs of steam / 34.5 = 145 hp boiler

Get A Quote

ALL YOUVE EVER NEEDED TO KNOW ABOUT STEAM BUT …

before it was boiled. So, a boiler which can boil 10,000 pounds of water in one hour is rated at 10,000 pounds per hour. To further confuse the issue, we sometimes speak of Boiler Horse Power (BHP) when we refer to a boilers capacity. One BHP is equal to 34.5 pounds per hour of steam, so 10,000 pounds per hour of steam is the same as 289.9 BHP.

Get A Quote

Related Information